CSY series halogen moisture analyzer operating procedures: First, the use of CSY series halogen moisture analyzer CSY series halogen moisture meter measurement: 1. In the weighing (standby) state, open the heating chamber, place the sample on the weighing pan, close the heating chamber, and wait for the balance to stabilize. Press the (Start) button to start the measurement. 2. At this time, not only the heating symbol can be seen on the display, but also the real-time temperature change of the heating chamber, heating time and real-time moisture results can be seen. 3. When the preset shutdown mode parameter condition is reached, the instrument will automatically stop heating and make a sound, indicating that the measurement is over. At this point, the heating symbol stops flashing, and an alarm is issued to lock the relevant measurement result and wait for reading. Press the (Reset) button to undo the locked state and return to the weighing (standby) state. At this point the heating unit is turned off, but the temperature changes over time and the temperature display reflects the actual temperature of the current heating chamber. (Note: * During the measurement, press the (Reset) button to terminate the measurement at any time, but the display result will not be retained. * The heated sample tray and sample are still hot and need to be cooled before the sample can be removed.) Deep Fen Instrument Halogen Moisture Analyzer General Measurement: 1. Turn on the power, press the (on) button to turn it on, the instrument enters the weighing (standby) state, and warm up for 30 minutes. 2. In the weighing (standby) state, clear the items on the weighing pan, press the (TARE) button to make the instrument display value "0.000g" and keep flashing. At this time, open the heating chamber and place the 100g standard weight. On the weighing pan, the instrument performs weighing calibration. After the calibration is completed, the display stops flashing, and a “beep†sound is emitted, and then the weight is removed. 3. Place the sample on the weighing pan. The value displayed by the instrument is the quality of the sample. Press the (Tare) button. The instrument displays “0.000g†(ie the weight of the current sample is deducted as the tare weight), and then the second time. With the addition of the sample, the instrument displays the second sample quality and the instrument can be continuously peeled at a maximum weight of 110g. When the total mass of the sample on the weighing pan exceeds 120g, the instrument displays the overload warning symbol “Hâ€. Second, CSY series halogen moisture analyzer cleaning 1. Regularly clean the temperature sensor and heating chamber. The power plug must be unplugged before cleaning. Care should be taken to avoid damage to the instrument. Use a soft, lint-free cloth and a neutral detergent. Never use corrosive cleaning agents or solvents. Do not allow the cleaning agent to flow into the inside of the instrument. 3. CSY Series Halogen Moisture Analyzer Maintenance 1. Replace the fuse: This instrument has two fuses, one for the heating unit fuse (3A) and the other for the control circuit fuse (0.3A). When the instrument is powered on, press the (switch) button to display no, the control circuit fuse may burn out. If the heating unit does not work by pressing the (start) button, the heating unit fuse may burn out. CSY series halogen moisture analyzer replacement steps: 1 Unplug the power supply and unscrew the three screws that connect the instrument cover from the bottom of the instrument. 2 Remove the instrument cover (along with the heating unit). Pay attention to the switch face bar plug; 3 Screw out the burnt fuse with a screwdriver; 4 After replacing the fuses, restore the instrument in the reverse order. (Note: fuses of the same type and rating should be used. Deepen instruments remind you to ensure safe use of the instrument.) Fourth, CSY series halogen moisture analyzer notes 1. Instrument placement: stable, stable desktop, moisture-proof, no airflow. 2. Place the instrument in the selected location and adjust the horizontal foot so that the instrument's level indicator is in the center position. 3. The power supply should have a good grounding. 4. The instrument should be warmed up for half an hour before use. 5. The instrument is used to measure the moisture content of the sample, please do not use it. 6. For use by professionals who are familiar with the nature of the sample and trained. 7. Some samples require special care: flammable or flammable materials, solvent-containing matrices, matrices that produce flammable or explosive gases when heated, matrices containing toxic elements, and matrices that produce corrosive vapors upon heating and drying. Insect net greenhouse also known as plant and vegetables greenhouse net. Used for prevent the insect fly into the greenhouse during the plant growing, and cover the plants. Key off the approaches that the pests (adult insect) breeding. Effective control of the spread of all kinds of harmful pests spread, such as Cabbage caterpillar, diamondback moth, aphids, flea beetles, Sweet agnates, American leaf miner, literal etc and prevent the harmful of virus spread. Significantly reduced the use of chemical pesticides, so that the planting vegetables good-quality and health. Greenhouse Insect Net,Insect Mesh Netting,Insect Mesh JIANGSU SKYPLAN GREENHOUSE TECHNOLOGY CO.,LTD , https://www.thgreenhouse.com