First, the homogenizer operation specification 1 , start: whether the cooling water is normal, whether the power switch is normal. Loosen the handle of the secondary valve and the handle of the primary valve, and inject 2/3 of hot water (water temperature 75-8 5 °C ) into the hopper . Then start the electric vehicle, so that the material pipe water flows out normally, and the hot water in the hopper is circulated, so that the homogenizer is preheated to the ideal temperature and then the material is waited.
2 , homogenizer pressurization: the secondary valve first boosts. When there is no abnormal noise in the machine, the hot water is drained, and then the material is added. Note that when adding materials, ensure that the homogenizer is continuously fed and discharged to avoid mixing air. After the mixture of material and water is discharged, the material pipe and the hopper are recycled, and the secondary valve handle is gradually tightened. At this time, the pressure gauge displays the corresponding pressure value, and then gradually tighten the secondary valve handle until the pressure gauge displays The required pressure value is up. Note that the upper limit of its rated pressure must not be exceeded. The primary valve is boosting. Gradually tighten the primary valve handle pressure gauge to show the pre-pressure.
3. Discharge: After completing the above operation procedure, the material pipe is connected to the material container.
4. Pressure relief: When the homogenizer load is over, all working valve handles must be loosened. Loosen the first valve stem and loosen the secondary valve stem to make the pressure gauge display zero.
5. Cleaning: After the homogenizer is finished, apply clean water (using hot water, water temperature 65-75 °C ), clean the material of the pump body and working valve body, and drain the water.
6. Shutdown: Turn off the power and turn off the cooling water.

2. Homogenizer maintenance 1. The starting and pressing steps of the machine shall be in accordance with the operating procedures.
2. After the machine is used, the material passage should be cleaned with clean water in time. In particular, the valve seat and the valve core should be cleaned of residual materials to prevent sticking to ensure the next normal start.
3. If the machine is deactivated for a long time, a complete CIP cleaning should be done before use. A single alkali cleaning is performed every Wednesday, and a complete CIP cleaning is performed every Friday. 4 Always check the position of the lubricating oil in the gearbox and crankcase. The lubricating oil should be kept clean. If it is found to be deteriorated or fails, replace it with new oil and new ones. Sealing ring.
5. The homogenizer is overhauled once a quarter.
6. Do not use cleaning tools such as brushes and steel balls when cleaning the homogenizer.
More homogenizer information to

Municipal Waste Incinerator

MeCan Municipal Waste Incinerator is used for most of the domestic garbage, such as: kitchen waste, used towels, used clothing, plastic products, waste paper, etc, it is can be customized. And our incinerator with spray tower, deacidification tower, cyclone dust collector, bag filter and activated carbon adsorption, it is will reduce the temperature of flue gas from 700 ° C to 200 ° C, and effectively remove Dust, CO, SO2, HF, HCL, NO2.
Let's cooperate sincerely and protect our own earth, for our clear water and blue sky!

Municipal Incinerator,Municipal Waste Incinerator,Municipal Garbage Incinerator,Hospital Municipal Garbage Incinerator

Guangzhou MeCan Medical Limited , https://www.medical-waste-incinerator.com