Salt spray test machine specification

one. Name: salt water spray test machine

two. Specifications: HR -60

three. Inner box size : 600*450*400 (L*M*H) Outer box size : 710*560*560 (L*M*H)

four. Salt spray test electromechanical source: AC 220V 15A 50HZ

Fives. Detailed description:

One : body material :

1:5MM imported gray PVC board  

2: Support frame : ¢ 10.0MM tempered glass rod is corrosion resistant. Plastic steel V-frame and glass rods are placed to ensure that the specimen is at an angle of 30 degrees.

 

Two : Control system:  

1.DHC temperature controller, digital display PID automatic calculation, SSR output, high stability platinum temperature probe. The temperature error during the salt spray test is ± 1 °C.  

2. The pressure barrel adopts Henry's law, and is humidified by heating. The laboratory humidity reaches over 95% , which is in line with national standards.

III: Timing System: High-precision multi-function timer, test time can be set to multi-function, can be set 0.001S - 999.9H after power failure memory function with calls as power.

Continue to work before the time until the product is completed, and avoid the experiment after the power outage.  

Four: hydration system: automatic / manual watering system with automatic / manual hydration function when the water level is insufficient . The experiment is not interrupted to meet the diverse environmental requirements of the guests. ( automatic

Just add water to the water supply )

V: Heating method: When the salt spray experiment is carried out, the steam is directly heated, the heating rate is fast, the temperature distribution is uniform , and the standby time is shortened.

Six: Control mode : five-button standard operation . With full detection failure warning system. Lights up when a fault occurs . The five-button operation is a power switch, an operation switch, and a spray

Fog switch, timing switch, and defogging switch. Turn on the power switch during the experiment to automatically add water . After the water is added, turn on the operation switch . Set the experimental temperature and automatically warm the instrument.

Open the spray switch to start spraying equipment, open time, set time, after the end of the experiment to complete. Built-in manual demisting function can be placed or view the product during the experiment

Remove the experimental accumulation of salt spray.

Seven: safety protection device:  

1. With double over-temperature protection, the heating power can be automatically cut off when there is a temperature control table failure or a heating system failure. Avoid excessive temperature damage to the instrument.  

2. Double low water level protection to prevent dry burning of laboratory and pressure barrel heating tubes.  

3. With overload protection. Instruments and equipment to prevent damage to the internal parts when the electric abnormality. Any a low water level, the alarm is turned on the machine, and beep! Not easy to

Can be found in time next to the machine !

Eight: metering cylinder: two built-in mist collecting cylinders (JK-60 type one ) . It is less susceptible to damage than traditional external models.

Nine : Nozzle : Precision quartz glass nozzle . Guaranteed to use 4,000 hours without crystallization . Spray tower with cone disperser, with guiding fog, adjusting the amount of fog, and even fogging, etc.

Features.

A: a sealed manner: the inner and outer connector housing seal groove, with water leaking seal against salt spray.

Eleven : Control Panel and Electrical Accessories : Thermostat ( DHC )   Two   Pressure gauge (Taiwan)   One   Indicator light (Taiwan)   Six   Timer ( OMRON )   One   Accumulator   (Anliang)   One   Control switch   (Taiwan)   Five SSRs (Taiwan Yangming)   Two   Relay (Japan Omron)   Three   Temperature line (Taiwan Shenjie)   Two   Tune

Pressure valve ( AIRTAC )   Two   Solenoid valve ( AIRTAC )   Four   Water level device (Xiangyang, Taiwan)   Four   Heating pipe (titanium pipe)   Two EGO one

Twelve: Attachment Description: V -shaped rack   Four ( 60 type) O -shaped sticks 8 ( 60 type)   Sodium chloride   Two bottles of 5000ML measuring cups   a pH test strip   Two packs of 50ML graduated cylinders  

One ( 60 type)

Thirteen: Temperature range:

1 : Laboratory temperature: 35 °C - 50 °C (can be set arbitrarily)  

2 : Pressure tank temperature: 47 °C - 63 °C (can be set arbitrarily)

Fourteen: heating rate:  

1 : laboratory, room temperature - - → 35 °C   About 35 minutes  

2 : Pressure tank, room temperature - - → 47 °C   About 15 minutes

Fifteen: Temperature accuracy: ± 1 °C   Seventeen: This machine is suitable for neutral salt spray test ( NSS ) and corrosion test ( AASS , CASS ).  

• Standards of use: CNS3627 , 3885 , 4159 , 7669 , 8886 , JIS D-0201 , H-8502 , H-8610 , K-5400 , Z-2371 , ISO 3768 , 3769 , 3770 , ASTM B-117 , B-268 , GB-T2423 , GJB 150. Built-in functions:

The salt spray test machine is suitable for the surface treatment of various materials, including coatings, electroplating, organic and inorganic coatings, anodizing, anti-rust oil and other anti-corrosion treatments to test the corrosion resistance of the products.

Sixteen: main technical parameters:

Temperature range RT+10~55°C
Temperature uniformity ≤±2°C
Temperature fluctuation ≤±0.5°C
Salt spray settling rate 1~2ml/80cm2h
Saturated air pressure 0.8~2±0.01kg/cm2
Laboratory temperature Salt test method: 35±1°C/corrosion resistance test method: 50±1°C
Air barrel temperature Salt test method: 47±1°C/corrosion resistance test method: 63±1°C
Laboratory volume 108L
Filling bucket volume 15L  