1. The test object should not be over-squeezed in the box, so that the air flow is smooth, the heat inside the box is kept even, and the bottom plate of the inner chamber is close to the electric heater, so it is not suitable to place the test object. In the laboratory, the wind top flap should be properly opened to facilitate adjustment of the temperature inside the box. 1. The power supply is AC220V50HZ. It is necessary to use a 16-pin three-pin socket and a reliable grounding wire. Do not use the two-core socket without authorization. Laundry Detergent,Organic Detergent Liquid,Laundry Liquid Detergent,Detergent Liquid Wuxi Keni Daily Cosmetics Co.,Ltd , https://www.wxkenidaily.com
2. Do not open the temperature controller to prevent damage when it is not necessary.
3. When using the power, do not touch the electrical parts of the space on the left side of the box with your hands or use a damp cloth and rinse with water.
4. The power cord should not be wrapped around metal objects. Do not place it in a place with high temperature or humidity to prevent the rubber from aging and causing leakage.
5. When the incubator is filled with valuable strains and cultures, it should be observed frequently, abnormal conditions occur, and the power supply should be cut off immediately to avoid unnecessary or unnecessary losses.
6. When the temperature is high, care should be taken to avoid burns.
7. After each use, the power must be cut off. Always keep the inside and outside of the box clean and the water in the tank clean.
8. After the packaged incubator, under the conditions of the preservation and use rules, the manufacturer shall replace or repair the parts for the user free of charge when the product fails to work normally from the date of shipment (one year of use).
9. The fuse tube is installed in the left space of the box. When switching, the side door needs to be opened and the power must be cut off.
Installation and commissioning of electric heating constant temperature incubator
2. Be careful not to use force on the glass during transportation, and do not hit the cabinet.
3. After the equipment is grounded, it should be placed as stable as the ground is uneven.
4. This equipment should be kept away from electromagnetic interference sources, and the grounding wire of the equipment should be effectively grounded.
5. When the equipment is in normal operation, the load placed in the box should not affect the air circulation to ensure uniform temperature inside the box.
6, the power cord should not be close to the back, do not let the instrument or other items on the power line, so as not to damage the power cord.
7. Please do not use the instrument in direct sunlight or hot and humid places.